E Series

Fully Customized and Modular Design
Fully customized solution fit your site layout and electrical resources (e.g., 2000kW, 2400kW, Max3200kW) for rapid deployment, reducing construction costs and enabling scalable expansion to meet business growth.
Integrated Plug-and-Play Solution
Pre-integrated hydro server racks, CDU, switchboards, network, connection pipelines, and other key infrastructure,all pre-tested for rapid
deployment.
HeatCore E Series high-density indoor hydro cooled Bitcoin mining rack with integrated manifold, PDU, and server slots

RACK

Manifold & Quick Connector (female) 
PDU
Server Slots (Including 1U space for access layer swtich)

 

Scalability & High-Density Space    
It features a modular design for easier production, repair, and future expansion. 
Each Rack integrates 2U Server Slots, PDU, Manifold, Switch, and supports up to 20 servers.

Premium Quality for Reliability    
With the rack constructed from Q235 steel, manifold from 304 Stainless steel, branch hoses from EPDM material, the it rack is designed for premium high strength and corrosion- resistance.

PLC-controlled CDU hydro cooling system for indoor modular Bitcoin mining solutions

CDU

Coolant Distribution Unit (pump, expansion tank, filling tank, air vent valve, sensors, Y Strainer etc)

 

Stable Thermal & Pressure Control    
Innovative PLC-based control logic ensures automatic coolant replenishment, temperature fluctuation (within ±2℃) and supply-return pressure difference (within 1.0 bar) control, guaranteeing stable server operation.

O&M with Visibility & Serviceability    
With the touchscreen HMI(Human Machine Interface ) and HeatCore Cloud, operators could have easy access to set critical data(pressure difference, target temperature, pump), monitor the trend curve , get notified for the alarms.

Zero-Downtime Maintenance
Hot-swappable components and online maintenance design  Y-strainer ensure stable operation and easy upkeep, reducing the risk of interrupting services.

Prefabricated stainless steel connection pipeline for indoor hydro cooling Bitcoin mining infrastructure

CONNECTION PIPELINE

Connection Pipeline Including:
Connection Between CDU and Server Rack
Connection Between CDU and Dry Cooler

 

Piping: Prefabricated High Quality Material & Reliable Design
The main pipeline is constructed with sanitary-grade 304 stainless steel. Fluid simulation analysis is applied to ensures uniform flow distribution across branches.

Space-Optimized Layout
With connection pipelines installed beneath the N-Racks, and  copper busbars above, it  maximize space efficiency, reduces the risk of contact between electrical and water systems. uniform flow distribution across. branches

 

dry cooler 新替换元素

DRY COOLER

 

Zero or Reduced Water Consumption    
Environmentally sustainable and ideal for regions with water scarcity or strict regulations.
 

Broad Adaptability
Fully custmized solution to meet the needs of diverse climates, with intelligent control systems that auto-adjust to environmental changes for stable operation all year round. round independent electrical protection.

 

Integrated power distribution, monitoring, and safety infrastructure inside HeatCore indoor mining solution

OTHER KEY INFRASTRUCTURE

① Power supply (main switchboards,  power meter integrated)                         
② Leakage Detection system
③ Lightning protection and grounding system
④ Network system

 

In additon to CDU and hydro server rack, the container also integrates other key infrastructure like network switches, leakage detection system, main switchboards (for power distribution to server rack, and CDU, eliminating individual cabling one rack by one rack, simplifying installation),  

This Pre-fabricated and pre-tested systems also ensure reliability and reduce the risk of installation errors, enhancing operational stability. 

Plate heat exchanger for Bitcoin mining heat reuse in indoor heating and industrial applications

PHE(OPTIONAL)

Plate Heat Exchnger

 

We would support customization case by case with precision and efficiency.

 

With the outlet water temperature of up to 80°C / 176 °F , significantly higher than the industry average, our system is an ideal choice for various heat utilization applications, including but not limited to agricultural heating, residential heating, and industrial process.  
The Plate Heat Exchanger provided by HeatCore could efficiently transfers heat,  between hot fluid from hydro servers and cold fluid from external systems via metal plates, ensuring optimal performance. 

                                                                                        

Rack

CDU

Connection Pipeline

Dry Cooler

Other Key Infrastructure

PHE(optional)

E Series

Experience the ES Series Indoor Solution

 

Each setup includes 10–12 hydro server rack, and every rack runs 20 WhatsMiner M63/M65 Series miners.

With modular design and adaptive control, ES offers real-time monitoring, energy management, and easy remote maintenance.

ABOUT ES2400

ES2400 SPECIFICATION
CATEGORY DETAILS
Model ES2400
Container‘s Capacity 240 units of M53/M63/M65 Series Miners
Main Components Included Smart Control System(CDU)/Switchgear/12*IT Rack/Dry Cooler
Size 9815x2200x2330mm(Fit to 40ft-HQ container)
Container‘s Net Weight/Operating Weight 12500kg/22500kg
Input Power 3-Ph/PE 380-480V 50/60Hz
Max. Power Consumption 2490kW
Max. Output Temperature 80°C(176 °F) (after plate heat exchanger, up to 75°C/ 167 °F)
Thermal Efficiency 95%
Heat Exchangers Customized on Demand
Dry Coolers Customized on Demand
Pipe System Customized on Demand
Electrical Code for the US NFPA 70, UL508A, UL2755, UL50E, UL891
Electrical Code for the EU IEC 61439, IEC 60204
Certification CE or CSA Field Evaluation
Note: Customizable Design According to Specific Requirements​​

ES Series Loading & Unloading

This one-minute video showcases the complete handling process of the ES Series — from forklift lifting and secure component installation for safe transport, to controlled unloading, site setup, and commissioning. Every step is executed with precision to ensure safety, structural integrity, and seamless deployment. The streamlined workflow reflects how the ES Series is engineered for efficient logistics and rapid on-site operation.

 

 

 

Notes :

 

 

 

 

 

 

 

 

1.The hydro cooling system and dry cooler could be placed on level ground. The ground should be hardened to support a minimum load of 35 tons to ensure stability.

2.Suitable for altitudes ≤2000 meters. For altitudes above 1000 meters, account for a capacity reduction of approximately 1% for transformers and switches per additional 100 meters.

3.Operates in temperatures from −25 to 45 °C (−13 to 113 °F) and relative humidity of 10%RH to 85%RH(non-condensing). 

4.The ambient temperature of the HeatCore hydro cooling system does not equate to the Whatsminer M6X hydro server’s operating environment temperature.

5.Liquid coolant is pure water (or distilled water)+ special corrosion inhibitor, In environments below 0 °C (32 °F), consider antifreeze(select a ratio according to a freezing point).

6.Regular maintenance and inspections are required to prevent corrosion or scaling, extending equipment lifespan.

7.Ensure at least 4-6 meters of air inlet space on both long sides of the dry cooler to maintain efficient heat dissipation.

8.Coolant volume, regarding hydro cooling system, for instance ES2000 + DC2000 (200 servers) , ES2400 + DC2400 (240 servers) , the required coolant volume is approximately 2,300L to 2,500L.

9.PUE stands for Power Usage Effectiveness, defined as the ratio of total hydro cooling system's energy consumption to IT server load energy usage.

10.Normally,  lower PUE (closer to 1) indicates better energy utilization, reducing operational costs. The PUE of HeatCore's hydro cooling is less than 1.05.
For instance, in ES2000 (200 servers) + DC2000, the non-IT support components like CDU pumps, dry cooler fans, PLC,  consume less than 100kW.

11.Flexible configuration, the qty of server slots and server racks within the ES skid system could be customized based on site power availability and transformer (or generator) capacity.