Outdoor Racks
OUTDOOR RACKS
This product is design for Stranded Energy mining scenario. If the provided power is less than 500kw, but you need to operate outdoor.You can choose this series, it Waterproof rating is up to IP54.
OUTDOOR RACK
This product is designed for Stranded Energy mining scenario. If the provided power is less than 500kW, but you need to operate outdoor. You can choose this series, its waterproof rating is up to IP54, ensuring protection against dust and water splashes.

Outdoor Deployment
Outdoor Rack Series supports 10 WhatsMiner miners, integrating hydro-cooling, PDU, and CDU with IP54 protection and C3 anti-corrosion for outdoor use

Customization Heating
Optional plate heat exchanger enables rapid deployment for heating needs (domestic, building, farm)

User-Friendly O&M
Front/Rear access and touchscreen HMI simplify data control (pressure, temperature, pump), trend monitoring, and alarm notifications
ABOUT OUTDOOR RACK ↘
OUTDOOR RACK SPECIFICATION
CATEGORY | DETAILS | ||
Model | MS100 | ||
Max Operating Current | 160A | ||
Dimensions (L x W x H) | 1000x1150x2300mm | ||
Net Weight/Operating Weight | 550kg/850kg | ||
Power Supply Voltage and Hertz | 3-Ph/PE 380-480V 50/60Hz | ||
Socket Outlet Voltage | 3-Ph/PE 380-480V 50/60Hz | ||
Inlet Water Temperature Range | Normal:20~50°C(Miner)/High:20~40°C(Miner) | ||
Certification | CE or CSA Field Evaluation |
OUTDOOR RACK
OUTDOOR RACK SPECIFICATION
Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |
OUTDOOR RACK: MS 100
Outdoor Deployment
Outdoor Rack Series supports 10 Whatsminer slots, integrating hydro-cooling, PDU, and CDU with IP54 protection and C3 anti-corrosion for outdoor use
Customizable Heating
Optional plate heat exchanger enables rapid deployment for heating needs (domestic, building, farm)
User-Friendly O&M
Front/rear access and touchscreen HMI simplify data control (pressure, temperature, pump), trend monitoring, and alarm notifications
MS 100










Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |