X SERIES
X series is our container solution. It is easy to move, plug and play. We have diverse size from 20-foot(1Mw~1.6Mw) to 40-foot(1.2MW dry cooler integrated, 2.4~3.6MW). The main power distribution cabinet is also integrated.
XS1000 & XS1200 & XS1600 & XS2400
X series is our containerized solution, designed for portability and plug-and-play. We have diverse size from 20-foot(1MW~1.6MW) to 40-foot(1.2MW dry cooler integrated, 2.4~3.6MW). The main power distribution cabinet is also integrated.

Outdoor Rapid Deployment
Pre-fabricated CDU, IT rack, electrical, and network systems in a 40/20 HQ container enable rapid on-site installation without new construction

Energy Efficient
Supports up to 20 Whatsminer servers per rack with hydro-cooling for low PUE (<1.05), zero water use, low noise, and reduced energy costs

Safe & Compliant
Fully compliant: UL-certified components, meets CSA standards and NEC/IEC regulations, CSA Field Evaluation supported.Water-electricity isolation design for safety

Intelligent O&M
Miner inlet & outlet water temperature fluctuation within ±2°C.
Automated replenishment, leak detection, overpressure protection, and pressure differential within ±1 bar
ABOUT XS1200 ↘
CATEGORY | DETAILS | ||
Model | XS1200 | ||
Container‘s Capacity | 120 units | ||
Main Components Included | Smart Control System(CDU)/Switchboard/6*IT Rack/Dry Cooler | ||
Container‘s Size | 40ft-HQ | ||
Container‘s Net Weight/Operating Weight | 14000kg/18200kg | ||
Input Power | 3-Ph/PE 380-480V 50/60Hz | ||
Max. Power Consumption | 1256kW | ||
Max. Output Temperature | 75°C | ||
Thermal Efficiency | 95% |
||
Heat Exchangers | Customized on Demand | ||
Dry Coolers | Customized on Demand | ||
Pipe System | Customized on Demand |
||
Electrical Code for the US | NFPA 70, UL508A, UL2755, UL50E, UL891 | ||
Electrical Code for the EU | IEC 61439, IEC 60204 | ||
Certification | CE or CSA Field Evaluation | ||
Note: Customizable Design According to Specific Requirements |
XS 1000 & XS 1200 & XS 1600 & XS 1200
Outdoor Rapid Deployment
Pre-fabricated CDU, IT rack, electrical, and network systems in a 40/20 HQ container enable rapid on-site installation without new construction
Energy Efficient
Supports up to 20 Whatsminer servers per rack with hydro-cooling for low PUE (<1.05), zero water use, low noise, and reduced energy costs.
Safe & Compliant
Fully compliant: UL-certified components, meets CSA standards and NEC/IEC regulations, CSA Field Evaluation supported.
Water-electricity isolation design for safety
Intelligent O&M
Miner inlet & outlet water temperature fluctuation within ±2°C.
Automated replenishment, leak detection, overpressure protection, and pressure differential within ±1 bar




Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |
XS 1200




Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |
XS 1600




Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |
XS 2400




Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |
XS1200 System Operation Diagram ↙


ABOUT XS1000 ↘

CATEGORY | DETAILS | ||
Model | XS1000 | ||
Container‘s Capacity | 100 units | ||
Main Components Included | Smart Control System(CDU)/Switchboard/5*IT Rack/Dry Cooler | ||
Container‘s Size | 20ft-HQ | ||
Container‘s Net Weight/Operating Weight | 5000kg/8050kg | ||
Input Power | 3-Ph/PE 380-480V 50/60Hz | ||
Max. Power Consumption | 1050kW | ||
Max. Output Temperature | 75°C | ||
Thermal Efficiency | 95% |
||
Heat Exchangers | Customized on Demand | ||
Dry Coolers | Customized on Demand | ||
Pipe System | Customized on Demand |
||
Electrical Code for the US | NFPA 70, UL508A, UL2755, UL50E, UL891 | ||
Electrical Code for the EU | IEC 61439, IEC 60204 | ||
Certification | CE or CSA Field Evaluation | ||
Note: Customizable Design According to Specific Requirements |
ABOUT XS1600 ↘

CATEGORY | DETAILS | ||
Model | XS1600 | ||
Container‘s Capacity | 160 units | ||
Main Components Included | Smart Control System(CDU)/Switchboard/8*IT Rack/Dry Cooler | ||
Container‘s Size | 20ft-HQ | ||
Container‘s Net Weight/Operating Weight | 8000kg/12670kg | ||
Input Power | 3-Ph/PE 380-480V 50/60Hz | ||
Max. Power Consumption | 1656kW | ||
Max. Output Temperature | 75°C | ||
Thermal Efficiency | 95% |
||
Heat Exchangers | Customized on Demand | ||
Dry Coolers | Customized on Demand | ||
Pipe System | Customized on Demand |
||
Electrical Code for the US | NFPA 70, UL508A, UL2755, UL50E, UL891 | ||
Electrical Code for the EU | IEC 61439, IEC 60204 | ||
Certification | CE or CSA Field Evaluation | ||
Note: Customizable Design According to Specific Requirements |
ABOUT XS2400 ↘

CATEGORY | DETAILS | ||
Model | XS2400 | ||
Container‘s Capacity | 240 units | ||
Main Components Included | Smart Control System(CDU)/Switchboard/12*IT Rack/Dry Cooler | ||
Container‘s Size | 40ft-HQ | ||
Container‘s Net Weight/Operating Weight | 12000kg/19200kg | ||
Input Power | 3-Ph/PE 380-480V 50/60Hz | ||
Max. Power Consumption | 2488kW | ||
Max. Output Temperature | 75°C | ||
Thermal Efficiency | 95% |
||
Heat Exchangers | Customized on Demand | ||
Dry Coolers | Customized on Demand | ||
Pipe System | Customized on Demand |
||
Electrical Code for the US | NFPA 70, UL508A, UL2755, UL50E, UL891 | ||
Electrical Code for the EU | IEC 61439, IEC 60204 | ||
Certification | CE or CSA Field Evaluation | ||
Note: Customizable Design According to Specific Requirements |
XS1000 Container Internal Structure ↙


XS1600 Container Internal Structure ↙


XS2400 Container Internal Structure ↙


Category | Details |
Model | HS05 |
Rack Capacity | 1 Unit M64 series |
Main Components Included | Smart Control System(CDU), PDU, etc. |
Dimensions (L x W x H)-mm | 480*600*545 |
Dimensions(without dry cooler) (W x D x H)-mm | |
Net Weight/Operating Weight-kg | 35 kg/ 50 kg |
Net Weight/Operating Weight(without dry cooler)-kg | |
Input power | Single Ph/N/PE 200-240V 50/60Hz |
Max Power Consumption | 6 kw |
Maximum output Temperature | |
Thermal Efficiency | 95% |
No. of heat exchanger | 2 |
Electrical Code for the US | |
Electrical Code for the EU |